问题描述:用matlab标定箱做双目标定时,出现:
Disabling view 2 - Reason: the left and right images are found inconsistent (try help calib_stereo for more information)
问题分析:用 help calib_stereo for more information查看错误原因,发现如下:
If the Warning message "Disabling view kk - Reason: the left and right images are found inconsistent" is encountered, that probably means that for the kkth pair of images, the left and right images are found to have captured the calibration pattern at two different locations in space. That means that the two views are not consistent, and therefore cannot be used

在使用Matlab进行双目标定时,遇到'Disabling view 2 - Reason: the left and right images are found inconsistent'错误。该错误意味着左右图像捕捉到的校准图案位于空间的不同位置,无法用于立体校准。解决方法包括检查图像对是否对应正确,或者调整go_calib_stereo.m文件中的阈值设置。如果图像对反向,也会导致此错误。警告中的矩阵奇异值问题可能影响结果的准确性。
最低0.47元/天 解锁文章
3109

被折叠的 条评论
为什么被折叠?