RS-485 Unit Load

本文详细解释了TIA/EIA-485-A标准下单位负载的概念,包括其在不同电压条件下的定义与模型,并介绍了如何通过测量输入电流来确定连接到RS-485总线的单位负载数量。通过实例展示了电流测量和比例计算的过程。

摘要生成于 C知道 ,由 DeepSeek-R1 满血版支持, 前往体验 >

The unit load
TIA/EIA-485-A defines a unit load as a 15-kΩ resistor connected
to a –3- or 5-V source (see Figure 2). The –3-V case
applies for positive input current, and the 5-V case applies
for negative bus current. The definition and model are
valid for input voltages from –7 to 12 V to account for driver
outputs between 0 and 5 V, with up to ±7 V of commonmode

noise voltage between a driver and receiver.


The number of unit loads (nUL) presented by any proposed
connection to the RS-485 bus is then determined as
the ratio of its measured input current and the current of
1 unit load. Since the current of 1 unit load is a function of
voltage, the input current must be measured and the ratio
determined throughout the entire –7- to 12-V input-voltage
range, with the highest ratio determining the unit-load rating.
Figure 3 shows a hypothetical example where the measured
input current of a circuit is nonlinear. It can be
shown (see sidebar on next page) that, at its maximum
value, the ratio of the measured and unit-load current is
equal to the ratio of the slopes of the two functions and
lies on a line with an intercept at –3 V for positive current
and 5 V for negative current. Conceptually, this amounts to
rotating a line pivoted at I = 0 mA and V = –3 V until it is
tangent to the curve of measured positive current versus

Receiver (Rx) Features TP8485E utilize a differential input receiver for maximum noise immunity and common mode rejection. Input sensitivity is better than ±200mV, as required by the RS-422 and RS-485 specifications. Rx outputs feature high drive levels (typically 25mA @ VOL = 1V) to ease the design of optically coupled isolated interfaces. Receiver input resistance of 100kΩ surpasses the RS-422 specification of 4kΩ, and is eight times the RS-485Unit Load (UL)” requirement of 12kΩ minimum. Thus, these products are known as “one-eighth UL” transceivers, and there can be up to 256 of these devices on a network while still complying with the RS-485 loading specification. Rx inputs function with common mode voltages as great as ±7V outside the power supplies (i.e., +12V and -7V), making them ideal for long networks where induced voltages are a realistic concern. All the receivers include a “full fail-safe” function that guarantees a high level receiver output if the receiver inputs are unconnected (floating), shorted together, or connected to a terminated bus with all the transmitters disabled. Receivers easily meet the data rates supported by the corresponding driver, and all receiver outputs are three-stable via the active low RE input. Driver (Tx) Features TP8485E driver is a differential output device that delivers at least 2.5V across a 54Ω load (RS-485), and at least 2.8V across a 100Ω load (RS-422). The drivers feature low propagation delay skew to maximize bit width, and to minimize EMI, and all drivers are three-stable via the active high DE input. Full Fail-Safe All the receivers include a “full fail-safe” function that guarantees a high level receiver output if the receiver inputs are unconnected (floating), shorted together, or connected to a terminated bus with all the transmitters disabled. Receivers easily meet the data rates supported by the corresponding driver, and all receiver outputs are three-statable via the active low RE input.