1A customer calls to MB4-175 MB7-222 MB7-224 inform. you that their Sun Fire V240 has panicked. They have not written down any of the error messages and can only remember small parts of the errors that they saw. The customer makes reference to the following:
Fault_PC 0x1027238 Esynd 0x0019 MB/P0/B1/D1: B1/D1
Error on MB/P0/B1/D1: B1/D1 is Persistent
Based on the small 920-203 920-533 amount of information the customer has been able to provide you, where in the system does the error most likely reside?
A: PCI card
B: Motherboard
C: CPU module
D: Memory module
E: Internal disk drive
Correct Answers: D
2.You need to email a 3.6 MB file, explorer.hostid.tar.gz, to an escalation engineer for 70-305 70-500 . However, at the customer site, file attachments cannot exceed 2MB, so you decide to split the file into two 1.8MB segments.
Which command can you use?
A: split -k explorer.hostid.tar.gz
B: split explorer.hostid.tar.gz -1.8m
C: split -b 1.8k explorer.hostid.tar.gz
D: split -b 1.8m explorer.hostid.tar.gz
Correct Answers: D
3 You have added a CPU to a Sun HP0-302 HP0-538 Fire V440 and need to verify that the number of CPUs physically installed corresponds to the number of CPUs seen in Solaris.
Which two commands will show you how many 000-297 1z0-147 310-301 CPUs are seen in Solaris? (Choose two.)
A:pset
B:psrinfo
C:cpulist
D:psradm -a
E:prtdiag -v
Correct Answers: B, E
4 .You receive a call from a customer saying that the power supply amber fault LED is lit on a Sun Fire V240.
What should you ask the customer to do to confirm that the fault is genuine?
A: Reseat the power supply.
B: Show the FRU using prtfru.
C: Power cycle the Sun Fire V240.
D: Display system information using prtdiag.
Correct Answers: D
本文提供SunFire V240服务器故障排查步骤,包括内存错误定位、文件分割命令使用、CPU数量验证及电源故障确认方法。
1490

被折叠的 条评论
为什么被折叠?