随时待补充:
1、查看端口状态
<CoreSwitch-S7706>dis int XGigabitEthernet 1/5/0/18
XGigabitEthernet1/5/0/18 current state : DOWN
Line protocol current state : DOWN
看到down字眼,即为端口是关闭状态,up是开启状态
2、查看收发光功率
<CoreSwitch-S7706>dis transceiver interface XGigabitEthernet 1/5/0/18 verbose
Diagnostic information:
Temperature(C) :47
Voltage(V) :3.34
Bias Current(mA) :30.23
Bias High Threshold(mA) :90.00
Bias Low Threshold(mA) :5.00
Current Rx Power(dBM) :-40.00
Default Rx Power High Warning(dBM) :-0.50
Default Rx Power Low Warning(dBM) :-16.99
Default Rx Power High Threshold(dBM) :0.00
Default Rx Power Low Threshold(dBM) :-17.50
Current Tx Power(dBM) :-1.42
Default Tx Power High Warning(dBM) :2.50
Default Tx Power Low Warning(dBM) :-7.50
Default Tx Power High Threshold(dBM) :3.00
Default Tx Power Low Threshold(dBM) :-8.00
User Set Rx Power High Threshold(dBM) :0.00
User Set Rx Power Low Threshold(dBM) :-17.50
User Set Tx Power High Threshold(dBM) :3.00
User Set Tx Power Low Threshold(dBM) :-8.00
Current Rx Power(dBM)代表收光功率,值如果是-40则说明基本完全不可用,Current Tx Power(dBM)代表发光功率