温升和温控

文章讨论了如何通过adb命令获取温控引擎配置,以理解用户空间规则可能触发的模组缓解措施。当nsp/camera/videosensor温度过高达到100C时,会执行level3动作对PA冷却设备进行控制。尽管modem温度正常,但怀疑其他组件温度过高。为获取更多线索,建议使用tsenslog和ctlogger工具收集日志数据。

摘要生成于 C知道 ,由 DeepSeek-R1 满血版支持, 前往体验 >

温控策略获取:

  1.  Provide  thermal engine configuration to understand user space rules might be initiating the modem mitigation.
     adb shell thermal-engine -o > thermal-config.txt
    (or)
    adb shell thermal-engine-v2 -o > thermal-config.txt
     
  2. Also please let us know if any rules defined in config.ini at the path of /nv/item_files/therm_monitor/config.ini.

From the thermal engine configuration, level3 action on PA cooling device will be taken if nsp/camera/video sensor temperatures are high and at 100C.

There were other rules from modem side but from the logs, modem temperatures are not high. So we suspect temperature of other components are high.

TO get more clues on this, please help to get tsens log with attached ctlogger tool.

评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00