Figure 1 Positioning the Module in a Horizontal Slot Chassis

Figure 2 Clearing the EMI Gasket in a Horizontal Slot Chassis

Figure 3 Ejector Lever Closure in a Horizontal Slot Chassis

Figure 4 Positioning the Module in a Vertical Slot Chassis

Figure 5 Clearing the EMI Gasket in a Vertical Slot Chassis

Figure 6 Ejector Lever Closure in a Vertical Slot Chassis

Enter the show module or show port [mod_num/port_num] command to verify that the system acknowledges the new modules and has brought them online.
This example shows the output of the show module command:
Console> show module
Mod Slot Ports Module-Type Model Sub Status
--- ---- ----- ------------------------- ------------------- --- --------
1 1 2 1000BaseX Supervisor WS-X6K-SUP1A-2GE yes ok
15 1 1 Multilayer Switch Feature WS-F6K-MSFC no ok
8 8 48 10/100BaseTX Ethernet WS-X6248-RJ-45 no ok
9 9 48 10/100BaseTX Ethernet WS-X6348-RJ-45 yes ok
Mod Module-Name Serial-Num
--- ------------------- -----------
1 SAD03436055
15 SAD03432597
9 SAD03414268
Mod MAC-Address(es) Hw Fw Sw
--- -------------------------------------- ------ ---------- --------------
1 00-30-80-f7-a5-06 to 00-30-80-f7-a5-07 1.0 5.2(1) 6.1(0.12)
00-30-80-f7-a5-04 to 00-30-80-f7-a5-05
00-30-a3-4a-a0-00 to 00-30-a3-4a-a3-ff
15 00-d0-bc-ee-d0-dc to 00-d0-bc-ee-d1-1b 1.2 12.0(3)XE1 12.0(3)XE1
8 00-d0-c0-c8-83-ac to 00-d0-c0-c8-83-db 1.1 4.2(0.24)V 6.1(0.37)FTL
9 00-50-3e-7c-43-00 to 00-50-3e-7c-43-2f 0.201 5.3(1)
Mod Sub-Type Sub-Model Sub-Serial Sub-Hw
--- ----------------------- ------------------- ----------- ------
1 L3 Switching Engine WS-F6K-PFC SAD03451187 1.0
9 Inline Power Module WS-F6K-VPWR 1.0
Console>
Checking Connectivity
To check connectivity on any switching module port, perform these tasks:
Task |
Command |
---|---|
• ![]() |
ping host |
• ![]() |
show interface show ip route |
For example, to ping a host named server1, enter this command:
Console> ping server1
server1 is alive
Console>