一台dell 6950机器突然不断地报
Jun 26 20:54:46 asoftdw_pri kernel: sdh : READ CAPACITY failed.
Jun 26 20:54:46 asoftdw_pri kernel: sdh : status=0, message=00, host=7, driver=00
Jun 26 20:54:46 asoftdw_pri kernel: sdh : sense not available.
Jun 26 20:55:16 asoftdw_pri kernel: sdh: Write Protect is off
Jun 26 20:55:16 asoftdw_pri kernel: sdh: assuming drive cache: write through
Jun 26 20:55:16 asoftdw_pri kernel: sdh:<3>Buffer I/O error on device sdh, logical block 0
Jun 26 20:55:16 asoftdw_pri kernel: Buffer I/O error on device sdh, logical block 0
Jun 26 20:55:16 asoftdw_pri kernel: Buffer I/O error on device sdh, logical block 0
Jun 26 20:55:16 asoftdw_pri kernel: unable to read partition table
这样的错误。
[@more@]Fdisk -l也是hang在那里。
Df -h看不到sdh的设备。
由于上面挂了emc的cx3-80,所以查看emc的设备:
root@asoftdw_pri:/var/log> powermt display dev=all
Pseudo name=emcpowerb
CLARiiON ID=CK200071101314 [Storage Group 1]
Logical device ID=600601602CC41D0026B67163E10CDC11 [LUN 1]
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP B, current=SP B
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
### HW Path I/O Paths Interf. Mode State Q-IOs Errors
==============================================================================
1 qla2xxx sdb SP A0 active alive 0 0
2 qla2xxx sde SP B0 active alive 0 0
Pseudo name=emcpowera
CLARiiON ID=CK200071101314 [Storage Group 1]
Logical device ID=600601602CC41D00DE825B46E50CDC11 [LUN 0]
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
### HW Path I/O Paths Interf. Mode State Q-IOs Errors
==============================================================================
1 qla2xxx sdc SP A0 active alive 0 0
2 qla2xxx sdf SP B0 active alive 0 0
Pseudo name=emcpowerc
CLARiiON ID=CK200071101314 [Storage Group 1]
Logical device ID=600601609BAC1C00A09A36E9B506DD11 [LUN 3]
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
### HW Path I/O Paths Interf. Mode State Q-IOs Errors
==============================================================================
1 qla2xxx sdd SP A0 active alive 0 0
2 qla2xxx sdg SP B0 active alive 0 0
也没有sdh设备
在dmesg中发现
USB Mass Storage device found at 6
scsi4 : SCSI emulation for USB Mass Storage devices
Vendor: Dell Model: Virtual Floppy Rev: 123
Type: Direct-Access ANSI SCSI revision: 02
Attached scsi removable disk sdh at scsi4, channel 0, id 0, lun 0
由于可以看出linux将虚拟的软驱当成了sdh,它认为是USB的硬盘。
查看scsi设备
root@asoftdw_pri:/var/log>cat /proc/scsi/scsi
Attached devices:
Host: scsi0 Channel: 00 Id: 08 Lun: 00
Vendor: DP Model: BACKPLANE Rev: 1.00
Type: Enclosure ANSI SCSI revision: 05
Host: scsi0 Channel: 02 Id: 00 Lun: 00
Vendor: DELL Model: PERC 5/i Adapter Rev: 1.00
Type: Direct-Access ANSI SCSI revision: 05
Host: scsi1 Channel: 00 Id: 00 Lun: 00
Vendor: DGC Model: RAID 10 Rev: 0324
Type: Direct-Access ANSI SCSI revision: 04
Host: scsi1 Channel: 00 Id: 00 Lun: 01
Vendor: DGC Model: RAID 10 Rev: 0324
Type: Direct-Access ANSI SCSI revision: 04
Host: scsi1 Channel: 00 Id: 00 Lun: 02
Vendor: DGC Model: RAID 5 Rev: 0324
Type: Direct-Access ANSI SCSI revision: 04
Host: scsi2 Channel: 00 Id: 00 Lun: 00
Vendor: DGC Model: RAID 10 Rev: 0324
Type: Direct-Access ANSI SCSI revision: 04
Host: scsi2 Channel: 00 Id: 00 Lun: 01
Vendor: DGC Model: RAID 10 Rev: 0324
Type: Direct-Access ANSI SCSI revision: 04
Host: scsi2 Channel: 00 Id: 00 Lun: 02
Vendor: DGC Model: RAID 5 Rev: 0324
Type: Direct-Access ANSI SCSI revision: 04
Host: scsi3 Channel: 00 Id: 00 Lun: 00
Vendor: Dell Model: Virtual CDROM Rev: 123
Type: CD-ROM ANSI SCSI revision: 02
Host: scsi4 Channel: 00 Id: 00 Lun: 00
Vendor: Dell Model: Virtual Floppy Rev: 123
Type: Direct-Access ANSI SCSI revision: 02
的确是有虚拟的软件,这个虚拟的软驱和光驱是DRAC里面产生的。
可以如下关掉:登陆drac-->介质-->附加虚拟介质的钩去掉即可。
来自 “ ITPUB博客 ” ,链接:http://blog.itpub.net/100091/viewspace-1006324/,如需转载,请注明出处,否则将追究法律责任。
转载于:http://blog.itpub.net/100091/viewspace-1006324/
一台Dell 6950服务器频繁出现'Buffer I/O error on device sdh'错误,导致无法读取分区表。通过检查emc设备、scsi设备,发现问题是Linux将虚拟软驱识别为sdh设备。解决方法是登录DRAC,取消附加虚拟介质的设置,关闭虚拟软驱。