In this blog I would like to try some clarity in the processing of exit variables (EXIT_SAPLRRS0_001) to bring. The emerged with BW 7.30 BAdI RSROA_VARIABLES_EXIT_BADI has to deal with Exit variable not exactly simplified. In addition, the BAdI is unfortunately not documented in the SAP Help. Furthermore, it has now also changed 60 with the 7.4 domain RSCHAVL of CHAR to SSTRING.
All exit variables described here are used to the range of values of a report limit or expand the scope of permissions. In addition, the properties described here by Exit variables for Exit variables are to be used as part of the staging in DTP‘s or InfoPackages.
First, however, let us first of all deal with the different types of exit variables and their processing order.
1.1 Variablentypen
If I talk about exit variables I distinguish the following types of use:
- Ready for input
- Not ready for input
- Use for authorization or staging
Ready for input variables come then to use if the user should be given the opportunity to influence the outcome report individually. The basic concept of an input-ready variables provides the user determines the value for the variable, and the value could not be changed by internal processing processes (customer exit). In section 1.3, “Overriding input values“, I describe how this concept can be bypassed and the user-entered value of an input-ready variables in the customer exit can be overwritten.
Reday for input variables would be processed in I_STEP = 1 and I_STEP = 3, see Section 1.2 “processing steps (I_STEP)”.
Not ready for input variables come then to use if the value is to be determined by rules. Here rules are often defined (implemented) in which the variable values for input-ready variables not depending on ready for input variables are determined.
Not ready for input variables would be processed in I_STEP = 1 and I_STEP = 2, see Section 1.2 “processing steps (I_STEP)”.
Exit variables can also be used as part of authorization or to staging. At exit variables that must be considered are used here, that there is no interaction with a user is usually held. This means here is the processing order another.
Therefore, it must be ensured here that combinations as ready for input, mandatory and no default value (Default value) that cause a variable dialog is needed. Process of staging (DTP, InfoPackage) are usually scheduled processes in place that are executed by background–users.
Variables of usage authorization and staging are processed only in I_STEP = 0, see Section 1.2 “processing steps (I_STEP)”.
1.2 Processing steps (I_STEP)
Exit variables depending on the usage and purpose in one or more steps, the I_STEP‘s processed. In the section “Dependencies for Variables of Type Customer Exit” the SAP Help the I_STEP‘s are briefly explained. The description in the online help is unfortunately incomplete and omitted entirely on examples. Therefore, I will briefly explain each step again using examples.
1.2.1 Authorization and Staging (I_STEP = 0)
In I_STEP = 0 exit variables are processed in the authorization and are used in staging. Figure 1.1 shows the use of an exit variables within the authorization. For the processing of exit variables within the entitlement only the I_STEP = 0 is traversed.
Figure 1.1: Exit variables within the authorization
Figure 1.2 shows the use of an exit variables in staging the example of selection within an InfoPackage.
Figure 1.2: Exit variables within the Staging
1.2.2 Initialization (I_STEP = 1)
The I_STEP = 1 is used for initialization of variables and exit is run separately for each exit variable. In the first stage the input-ready variables and then not ready for input variables are processed, see Figure 1.7. (The order could be differ, depends on the release (here BW 7.31 SP06)!)
Figure 1.3 shows a typical example of initializing an input-ready variables. The variable is initialized with the current month of last year.
Figure 1.3: Initialization
1.2.3 Derivation of variable values (I_STEP = 2)
The I_STEP = 2 is used to derive the values for the non-input-ready variables Exit. Again, the variables are processed separately analogous to I_STEP = 1. To derive the values for non-input-ready variables Exit all previously detected variable values in the parameter I_T_VAR_RANGE available. In section 1.3, “Overriding values entered” I describe as well as input-ready variables can be processed here.
Figure 1.4 shows how the current variable (examination of the variable name is not shown here), the value is derived based on the value of the variable ZTKE_MONTH.
Figure 1.4: Derivation of variables
1.2.4 validation (I_STEP = 3)
The I_STEP = 3 is used to validate all recorded variables. In I_STEP = 3 all previously recorded values in the parameter I_T_VAR_RANGE are testing and validation.
The I_T_VAR_RANGE parameter contains only the variables that contain a value. That is here are the only variables included:
- value set by default value or
- value set by an implementation (I_STEP = 1 or I_STEP = 3) or
- user entered a value in the variable dialog
In I_STEP = 3 can not be changed, the values of the individual variables. It is possible to generate messages which would be display with the report–result or the variable dialog. In the event that the validation of the variables means that it makes no sense to run the report by throwing an exception (RAISE EXCEPTION) to prevent the report is run. The exception means that the user re-enters the values in the variables dialog.
Figure 1.5 shows the values for the two variables ZYEARFROM and ZYEARTO determined and then compared as in I_STEP = 3. If the FROM value greater than TO value of a message is issued and using the RAISE statement wrong_value prevents the report is run. The user has the opportunity to correct the value in the variable dialog.
Figure 1.5: Validation – Customer Exit
Figure 1.6 shows similar to the example in Figure 1.5, as in the object-oriented context to run the report can be prevented. The exception must be thrown here in the object-oriented context.
Figure 1.6: Validation – BAdI
1.3 Execution Order of I_STEP
Figure 1.7 shows the sequence in which the individual‘s I_STEP under a BEx reports. I distinguish the two phases:
- Präparation (preparation phase) and
- Validierung (Validation Phase)
The I_STEP‘s the preparation phase are run before the variable dialogue and I_STEP‘s validation phase will only go through if the values of the input-ready variables change in the variables dialog.
Figure 1.7: Processing of exit variables (I_STEP’s)
That is the calling SAP standard processing procedure initially assumes that the user accepts the default values of the variables dialog without changing. In this case, the validation phase is not run again!
The process steps of the validation phase will only go through if the values in the dialog variables were changed by the user.
1.4 Processing of process variables Exit
With BW 7.3 the BAdI RSROA_VARIABLES_EXIT_BADI was introduced and presented to the customer exit EXIT_SAPLRRS0_001. The blog Coexistence of BAdI RSROA_VARIABLES_EXIT_BADI and Customer-Exit EXIT_SAPLRRS0_001 shows how the BAdI and the customer exit behave in a BW 7.3 system.
Figure 1.8 shows the individual processing blocks which are executed as part of the variable processing of exit variables.
Figure 1.8: Variables processing
The standard processing process first checks whether an active BAdI implementation by Type RSROA_VARIABLES_EXIT_BADI is available. As a filter value here, the technical name of the InfoObject is used on the exit variable based currently being processed. From a technical perspective, this test is performed within the function block RRS_VAR_EXIT via GET BADI.
The blog New BAdI RSROA_VARIABLES_EXIT_BADI describes the manufacturing process of the BAdI‘s in the details.
1.5 Overriding input values
The basic principle for input-ready variables was initially that user entered values can not be overwritten. An input-ready variable is not processed by default after the variable dialog as a single variable.
In I_STEP = 3, the variable can indeed be validated but not be changed. If it is determined during validation that the user entered value is not meaningful, in the I_STEP = 3 is a message that the user generated informed. In addition, an exception will be thrown. The exception ensures that the variables dialog appears again.
With the introduction of the parameter E_CHECK_AGAIN (see Note 1272242 – Renewed Variablenverprobung in I_STEP = 2), the concept was canceled. The parameter allows the developer to the user-entered value of an input-ready variables after the variable dialog in I_STEP = 2 to overwrite as needed.
As described in Section 1.2 “processing steps (I_STEP)” input-ready variables only in I_TEP = 1 and I_STEP = 3 processed, the value only in I_STEP = 1 changes (initialiesiert) can be. To ensure that an input-ready variables in I_STEP = 2 is again processed must be in I_STEP = 1 for this variable is the export parameters E_CHECK_AGAIN (E_CHECK_AGAIN = ‘X’) are set. If the parameter is set E_CHECK_AGAIN so this is ready for input variable is processed into a not ready for input variables in I_STEP = 2 analogous to the variables dialog.
BW客户退出变量详解
本文详细介绍了SAP BW中客户退出变量的处理流程,包括不同类型的退出变量及其处理顺序。阐述了准备输入与未准备输入变量的区别,并解释了授权及预处理阶段的工作原理。
2541







Good document
Hi Torsten,
A great and very detailed blog!
I have a question to point 1.5 “Overriding Input Variables” – is it possible to include “E_CHECK_AGAIN = ‘X'” in i_step = 3? I have two variables which are both input-ready. The entered value in VAR1 is checked in i_step = 3 – if the entered value is not valid according to a simple condition, the entered value for VAR2, should be overwritten in i_step = 2.
Thanks.
Hi,
sorry for the delay.
there is no way to get access to more than one variable and be alowe to change a value.
Only step 3 provides all variable values but here you can not change any value. You’re only able to step back to step 2.
But try this workareound:
Ensure in step 1 that for both variable the flag E_CHECK_AGAIN is set.
Than both variale would be processed in step 2.
Ensure that VAR1 would be processed before VAR2 (I’m not 100% sure but I blieve you can reach out this by the variable order in the dialog)
Than store the result of your check in a static attribute of a ABAP class.
Now if VAR2 would be processed you can check the attribute and set the value for VAR2 if necessary.
Torsten
Very useful document! Thanks for the examples , they did help in easy understanding of the concepts
Hello Torsten,
we have got an Input ready variable that we would like to validate. As far as we understand this should be possible in I_STEP 3.
As seen in our debugging-process the process never gets to step 3.
In another SCN-entry there was a short note, that STEP 3 is only executed for NON-Input ready variables.
So we would like to ask you:
is Validation of Input – ready variables possible in STEP3?
+ If YES, what to do to make the code execute STEP 3 as well?
– If NO, is there a possibility to validate input-ready variables at all? Which one?
Thx a lot for your help,
Thomas
Hi,
STEP 2 would only be called for non-Input ready variable.
STEP_3 is responsible for all exit variable (input ready or not), it’s the validation step.
But you will not found your variable in the import parameter I_VNAM. In step 3 this parameter is always empty.
Step 3 would called for all variables together. You will find them in the importing table parameter I_T_VAR_RANGE.
Figure 1.7 shows the call order for the difference steps.
To prepare the system step 3 would be called before the variable dialog comes up.
Keep in mind that step 3 only would be called again after the variable dialog in case the value of at least one variable had been changed.
Also ensure that your break point is an external break point or you’ll use RSRT to test your query.
Regards
Torsten
Hi Torsten,
Good document ! Currently I am working on some time dependent master data selection scree variables and facing issues to determine the key date.
Here it is :
1. We have a fiscal year period variable – V1 in istep=1, this basically returns (current period -1 ) by default but it is input ready & can be changed by user.
2. We have a key date variable – V2 which is filled in istep=2, which basically picks the last date of the period entered in fiscal year period variable V1.
3. Now the issue is when the user tries to access the list of values (LOVs) from F4 help of time dependent master data in the input screen the key date is still not filled & probably picks the system date & in the master data the DATETO updated (validity) is always last day of previous period. So we get # values in prompt selection – LOVs for the attributes which are time dependent.
So I need to determine the key date based on V1 within input screen before execution. I am planning to code V2 in istep=1 and probably handle the sequencing through variable sequence. Not sure if it will work, any ideas or suggestion will help :).
Cheers,
Dheeraj
Hi Torsten and thanks for the great article!! I have one note and some questions in the context of authorizations.
The note:
In Figure 1.7. “i_step = 0” is depicted at the beginning of the preparation phase. For me it gets executed always at the very end and it seems t it is not part of the preparation but part of the validation phase.
The questions (with some context):
I want to develop a dynamic authorization concept, based on authorization table (1) and on user selection (2). The idea is, that different user groups use the same query and receive different authorizations based on their business roles. The authorizations of the business roles are maintained in the authorization table. So far so good.
The crux is in one particular case, where the user should receive dynamically either full ‘*’ or aggregation ‘:’ authorizations, based on dynamic query selection.
For example: We have a query with 3 InfoObjects (IO): SALES, COUNTRY, REVENUE. For both SALES and COUNTRY we have authorization objects filled with 2 customer exit variables. The authorization objects are not ready for input, as those should be filled in the customer exit, based on his authorizations.
A sales representative in Germany should see the REVENUE and all SALES ‘*’ for COUNTRY “Germany”, thus in the initial query selection screen the user receives all 3 InfoObjects, filtered for Germany.
When the user removes IO COUNTRY and IO SALES in the Query Navigation, the combined REVENUE for all COUNTRIES should be displayed, e.g. SALES and COUNTRY authorizations should be ‘:’.
If the user wants to see all SALES without the country, nothing should be displayed for missing authorizations, SALES = ‘:’.
If the user then takes again COUNTRY in the Query Navigation, the initial results should be displayed.
Do You know, if this kind of dynamic authorizations is even possible?
After the initial execution all STEPS 1, 2, 3 and 0 are processed in that order. This is the case, for we restrict the query selection based on COUNTRY in step 2. After every following user navigation, only i_step = 0 is executed. And as You have pointed out the execution works per variable, thus it is not always clear, which one will be processed first. Moreover, even if the processing of the variables can be controlled, i have not found a way to get the current selection of the user in the exit.
Hi Ivan,
I’m not the right/best expert for question related to authorization topics.
And I’d changed my focus a little bit ;-]
Therefore I would say it’s better to post your quest in the Questions & Answers area.
Sorry that I can not immediately help.
Torsten
Thanks anyhow, for the quick response