Troubleshooting:Attach EBS volume to a running instance----network configuration on CC and NC has changed

本文档详细介绍了当网络配置更改导致无法正确附加EBS卷时的错误处理方法。主要针对因网络接口变更引发的IP地址变化问题,提供了通过UEC Web UI更新Storage Controller设置的具体步骤。

摘要生成于 C知道 ,由 DeepSeek-R1 满血版支持, 前往体验 >

Troubleshooting

If the network configuration on CC and NC has changed, say either the interfaces changed, due to which the ip addresses have also changed. In such cases the following errors appear in nc.log

[EUCAERROR ] libvirt: operation failed: adding scsi disk failed: pci_add pci_addr=auto storage file=/dev/etherd/e0.8,if=scsi
failed to add file=/dev/etherd/e0.8,if=scsi
 (code=9)
[Fri Mar 26 10:57:39 2010][001621][EUCAERROR ] virDomainAttachDevice() failed (err=-1) XML=
[Fri Mar 26 10:57:39 2010][001621][EUCAERROR ] ERROR: doAttachVolume() failed error=1

In order to overcome this, the configuration has to be changed accordingly from the webUI. Access the webUI of UEC using https://:8443. On Configuration page, under Clusters section, replace the correct ip and interface name for Storage Controller.

See below screenshot.

from :  http://kiranmurari.wordpress.com/2010/03/26/attach-ebs-volume-to-a-running-instance/

评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值