Symptom
The following error is received when running jobs:
RUN-050406 Bad System
Cause
This error is most often caused when there is insufficient memory to run the job.
Resolution
*****CONFIGURATION******
Data Integrator (ActaWorks versions 4.x and 5.x)
Windows NT
**********RESOLUTION******
Here are the steps to follow:
1. Restart the Job Server.
2. Check the Windows NT Event Log for a Virtual Memory error.
3. Check to see that you have enough virtual memory on the machine to run the job.
4. From the log files, determine which DataFlow was executing when the job failed.
5. Review your job, checking the caching options that you have set for source tables and lookup functions.
6. Run the job again.