H3C S5560交换机风扇反转告警

本文介绍H3C交换机风扇方向错误导致的故障现象及解决过程。通过调整风扇优选气流方向与实际方向一致,成功修复了风扇状态告警问题。

摘要生成于 C知道 ,由 DeepSeek-R1 满血版支持, 前往体验 >

H3C出现:如下报错信息,

出现:


[H3C]fan prefer-direction slot 1 power%Jan  1 04:30:13:401 2013 H3C DEV/1/FAN_DIRECTION_NOT_PREFERRED: Fan 1 airflow direction is not preferred on slot 1, please check it.
%Jan  1 04:30:13:404 2013 H3C DEV/1/FAN_DIRECTION_NOT_PREFERRED: Fan 2 airflow direction is not preferred on slot 1, please check it.

[H3C]%Jan  1 04:30:46:202 2013 H3C DEV/5/FAN_RECOVERED: Fan 1 recovered.
%Jan  1 04:30:46:207 2013 H3C DEV/5/FAN_RECOVERED: Fan 2 recovered.

 

解决办法:

检查交换机风扇配置信息发现交换机风扇的实际气流方向为:Airflow Direction: Port-to-power;而配置用户下看到风扇模块的优选气流方向为:Prefer Airflow Direction: Power-to-port,两者不一致(交换机风扇反转),导致交换机风扇状态为:FanDirectionFault,风扇信号灯告警,交换机SYS信号灯告警。
处理方法:
因为风扇模块的实际气流方向是无法改变的,只能去改变风扇模块的优选气流方向和风扇实际气流方向一致,操作步骤如下:

[QIANZHI-B]

[QIANZHI-B]dis fan

Slot 1:

Fan 1:

State : FanDirectionFault //工作状态报错

Airflow Direction: Port-to-power //实际气流方向

Prefer Airflow Direction: Power-to-port //优选气流方向

Fan 2:

State : FanDirectionFault

Airflow Direction: Port-to-power

Prefer Airflow Direction: Power-to-port

调整交换机的优选气流方向:

[QIANZHI-B]fan prefer-direction ?

slot Specify the slot number

[QIANZHI-B]fan prefer-direction slot 1 ?

port-to-power From port to power

power-to-port From power to port

[QIANZHI-B]fan prefer-direction slot 1 port-to-power

[QIANZHI-B]

[QIANZHI-B]dis fan

Slot 1:

Fan 1:

State : Normal //工作状态正常

Airflow Direction: Port-to-power //实际气流方向

Prefer Airflow Direction: Port-to-power //优选气流方向

Fan 2:

State : Normal

Airflow Direction: Port-to-power

Prefer Airflow Direction: Port-to-power

修改配置后,交换机各指示灯恢复正常。