Dell的服务器太多,每次都得上dell的网站查找代码,索性直接粘贴过来

 

Cable and Board Presence - Message Code: "x1Axx"
Message Code Message String Message Priority Message Comments Minimum Action Required to Remove Message from LCD Exists in SEL? System Phase When Event Can Occur?
E1A10 PDBPwrCable High PDB power cable to the planar is missing or bad and system will not power on. Failing device is reseated/replaced/repaired. Yes Pre-Post
E1A11 PCIRsrConfig High PCI risers are not configured correctly; some invalid configurations prevent system power on. Failing device is reseated/replaced/repaired. Yes Pre-Post
E1A12 PCIRsrMissing High One or all of the PCI risers is missing. This prevents system power on. Failing device is reseated/replaced/repaired. Yes Pre-Post
E1A14 SAS Cable A Low SAS cable A is missing or bad. Failing device is reseated/replaced/repaired. Yes Any
E1A15 SAS Cable B Low SAS cable B is missing or bad. Failing device is reseated/replaced/repaired. Yes Any
E1A16 SAS Cable FB Low Flex bay SAS cable is missing or bad. Failing device is reseated/replaced/repaired. Yes Any
E1A17 PwrCable FB Low Flex bay power cable is missing or bad. Failing device is reseated/replaced/repaired. Yes Any
E1A18 PDBCtrl Cable High PDB control cable to the planar is missing or bad and system will not power on. Failing device is reseated/replaced/repaired. Yes Any
Temperature - Message Code: "x11xx"
Message Code Message String Message Priority Message Comments Minimum Action Required to Remove Message from LCD Exists in SEL? System Phase When Event Can Occur?
E1114 Temp Ambient Med Ambient temperature has a reached a point outside of the allowed range. Temperature returns to allowable range. Yes Any
E1116 Temp Memory High Memory has exceeded allowable temperature and has been disabled to prevent damage to the components. AC Cycle or SEL clear Yes Any
Voltages - Message Code: "x12xx"
Message Code Message String Message Priority Message Comments Minimum Action Required to Remove Message from LCD Exists in SEL? System Phase When Event Can Occur?
E1210 CMOSBatt Low CMOS battery is missing or the voltage is outside of the allowable range. Failing device is reseated/replaced/repaired. Yes Any
E1211 ROMBBatt Low PERC5I RAID battery charger has reported to the Server Management that the battery is either missing, can't charge the battery (possibly because of high temperatures), or the battery is bad. Failing device is reseated/replaced/repaired. Yes Any
W1228 ROMBBatt< 24 hr Low This is a predictive failure warning message telling the user that the PERC5I RAID battery has less then 24 hours of charge left init. We provide this message as a warning message to the customer. Battery charges to > 24 hours of sustained charge. Yes Any
E1214 1.5VPwrGd High 1.5 VV voltage regulator has failed. AC Cycle or SEL clear Yes Any
E1215 1.8VPwrGd High 1.8 VV voltage regulator has failed. AC Cycle or SEL clear Yes Any
E1216 3.3VPwrGd High 3.3 V voltage regulator has failed. AC Cycle or SEL clear Yes Any
E1217 5VPwrGd High 5 V voltage regulator has failed. AC Cycle or SEL clear Yes Any
E1218 PCIRsr5VPwrGd High PCI Riser 5 V voltage regulator has failed. AC Cycle or SEL clear Yes Any
E1219 BackplanePwrGd High Backplane voltage regulator has failed. AC Cycle or SEL clear Yes Any
E1221 Flex BayPwrGd High Flex Bay voltage regulator power good has failed. AC Cycle or SEL clear Yes Any
E1222 VCACHE #PwrGd High VCACHE # voltage regulator has failed. AC Cycle or SEL clear Yes Any
E1223 VRM #PwrGd High VRM # voltage regulator has failed. AC Cycle or SEL clear Yes Any
E1225 ESB 1.5VPwrGd High ESB 1.5 VV voltage regulator has failed. AC Cycle or SEL clear Yes Any
E1226 PCIRsr1.5VPwrGd High PCI Riser 1.5 VV voltage regulator has failed. AC Cycle or SEL clear Yes Any
E1227 LinearPwrGd High Linear voltage regulator(s) has failed. Represents status of multiple voltage regulators used in the video and LOM circuitry. AC Cycle or SEL clear Yes Any
E1228 0.9VPwrGd High Memory VTT voltage regulator has failed. AC Cycle or SEL clear Yes Any
E1229 CPU # VCORE High Processor # VCORE voltage regulator has failed. AC Cycle or SEL clear Yes Any
E122A CPU VTTPwrGd High Processor VTT voltage regulator has failed. AC Cycle or SEL clear Yes Any
E122B 0.9 V Over Voltage High 0.9 V regulator voltage has exceeded the allowable voltage range. AC Cycle or SEL clear Yes Any
E122C CPU Power Fault High A voltage regulator failure was detected when the processor regulator(s) was enabled. AC Cycle or SEL clear Yes Any
Fans - Message Code: "x13xx"
Message Code Message String Message Priority Message Comments Minimum Action Required to Remove Message from LCD Exists in SEL? System Phase When Event Can Occur?
E1310 RPM Fan ## Low RPM of fan ## is outside of the intended operating range. Fan RPM reading returns to a point inside of the intended operating range. Yes Any
E1311 RPM Fan Mod #A Low RPM of fan A in the # module is outside of the intended operating range. Fan RPM reading returns to a point inside of the intended operating range. Yes Any
E1311 RPM Fan Mod #B Low Same as above except for fan B of module #. Fan RPM reading returns to a point inside of the intended operating range. Yes Any
E1311 RPM Fan Mod #C Low Same as above except for fan C of module #. Fan RPM reading returns to a point inside of the intended operating range. Yes Any
E1311 RPM Fan Mod #D Low Same as above except for fan D of module #. Fan RPM reading returns to a point inside of the intended operating range. Yes Any
E1313 Fan Redundancy Low The system is no longer fan redundant. Another fan failure would put the system at risk of over-heating. Fan redundancy is regained, which requires all fans to be operating within the intended operating range. Yes Any
Processors - Message Code: "x14xx"
Message Code Message String Message Priority Message Comments Minimum Action Required to Remove Message from LCD Exists in SEL? System Phase When Event Can Occur?
E1410 CPU # IERR High Processor # has had an internal error (IERR), but this does not always mean that CPU is the problem .There are a large variety of issues that cause an IERR. AC Cycle or SEL clear Yes Any
E1414 CPU #Thermtrip High Processor # has encountered a Thermtrip(over-temperature) event. AC Cycle or SEL clear Yes Any
E1418 CPU # Presence High Processor # is missing/bad and the system is in an unsupported configuration. AC Cycle or SEL clear Yes Pre-POST
E141C CPU Mismatch High Processors are not compatible as defined by Dell .System is in an unsupported configuration. AC Cycle or SEL clear Yes Pre-POST
E141F CPU Protocol High BIOS has reported a processor protocol error. AC Cycle or SEL clear Yes POST, After POST
E1420 CPU Bus PERR High BIOS has reported a processor bus PERR (parity error). AC Cycle or SEL clear Yes POST, After POST
E1421 CPU Init High BIOS has reported a processor initialization error. AC Cycle or SEL clear Yes POST, After POST
E1422 CPU MachineChk High BIOS has reported a machine check error. AC Cycle or SEL clear Yes POST, After POST
System Memory - Message Code: "x21xx"
Message Code Message String Message Priority Message Comments Minimum Action Required to Remove Message from LCD Exists in SEL? System Phase When Event Can Occur?
E2110 MBECrdx DIMM ## & ## High One of the DIMMs in the set implicated by "## & ##" has had a multi-bit error (MBE).If no memory riser is present the “Crdx” string is left out of the message.“x” is the memory riser, A-Z. AC Cycle or SEL clear Yes POST, After POST
E2111 SBE Log DisableCrdx DIMM ## High BIOS has disabled memory single-bit error (SBE) logging and will not log anymore SBEE's until the system is rebooted.## represents DIMM implicated by BIOS .If no memory riser is present the “Crd x” string is left out of the message.“x” is the memory riser, A-Z. System reset Yes POST, After POST
E2112 MemSpareCrdx DIMM ## High BIOS has spared the memory because it has determined the memory had too many errors.## represents DIMM implicated by BIOS. If no memory riser is present the “Crdx” string is left out of the message.“x” is the memory riser, A-Z. System reset Yes POST, After POST
E2113 Mem Mirror Crd x DIMM ## & ## High BIOS has disabled memory mirroring because it has determined one half of the mirror has had too many errors. ## & ## represents DIMM pair implicated by BIOS. If no memory riser is present the “Crdx” string is left out of the message.“x” is the memory riser, A-Z. System reset Yes POST, After POST
I2114 MemRaid Low BIOS Memory RAID Bank User action, sensor return to normal Yes Any
I2115 MemAdded Card x Low Memory has been added while the system is running. AC Cycle or SEL clear Yes Any
I2116 MemRemoved Low Memory has been removed while the system is running. AC Cycle or SEL clear Yes Any
E2117 MemHot Plug Low Memory hot-plug operation has failed. AC Cycle or SEL clear Yes Any
E2118 Fatal NBMemCRC High Northbound FBD CRC error on non-redundant entry. One of the connections in the FBD link on the Northbound (towards the MCH) side is "broken".This is determined by the MCH when two CRC errors have been detected twice in a row. AC Cycle or SEL clear Yes POST, After POST
E2119 Fatal SBMemCRC High FBD alert on non-redundant entry. One of the connections in the FBD link on the Southbound (towards the AMB'son the FBDIMM's) side is "broken".This is determined by the MCH when two CRC errors have been detected twice in a row. AC Cycle or SEL clear Yes POST, After POST
Power Supplies - Message Code: "x16xx"
Message Code Message String Message Priority Message Comments Minimum Action Required to Remove Message from LCD Exists in SEL? System Phase When Event Can Occur?
E1610 PS # Missing Low Power supply # was removed or is missing from the system. Failing device is reseated/replaced/repaired. Yes Any
E1614 PS # Status Low Power supply # has failed. Failing device is reseated/replaced/repaired. Yes Any
E1618 PS # Predictive Low Power supply # has a failure that predicts a power down event in this supply (i.e. power supply fan failure or power supply over-temp). Failing device is reseated/replaced/repaired. Yes Any
E161C PS # Input Lost Low Power supply # is attached to the system but has lost its AC/DC input. Failing device is reseated/replaced/repaired. Yes Any
E1620 PS #Input Range Low Power supply #'s AC/DC input is outside of the allowable range. Failing device is reseated/replaced/repaired. Yes Any
E1624 PS Redundancy Low The power supply subsystem is no longer redundant. If the last supply fails the system will go down. Failing device is reseated/replaced/repaired. Yes Any
E1625 PS AC Current Low The power supply input power is above the allowed amount for the power supply. Failing device is reseated/replaced/repaired. Yes Any
BIOS - Message Code: "x17xx"
Message Code Message String Message Priority Message Comments Minimum Action Required to Remove Message from LCD Exists in SEL? System Phase When Event Can Occur?
E1710 I/O ChannelChk High BIOS has reported an I/O channel check. AC Cycle or SEL clear Yes POST, After POST
E1711 PCI PERR B## D## F## High BIOS has reported PCI parity error on a component that resides in PCI configuration space at bus ##, device ##, function ##. AC Cycle or SEL clear Yes POST, After POST
E1711 PCI PERR Slot # High BIOS has reported PCI parity error on a component that resides in slot #. Same as above. Same as above. Same as above.
E1712 PCI SERR B## D## F## High BIOS has reported a PCI system error on a component that resides in PCI configuration space at bus ##, device ##, function ##. AC Cycle or SEL clear Yes POST, After POST
E1712 PCI SERR Slot # High BIOS has reported a PCI system error on a component that resides in slot #. Same as above. Same as above. Same as above.
E1714 Unknown Err Low BIOS has determined there has been an error in the system but is unable to determine its origin. AC Cycle or SEL clear Yes POST, After POST
E171F PCIE Fatal Err B## D## F## High BIOS has reported a PCIe fatal error on a component that resides in PCI configuration space at bus ##, device ##, function ##. AC Cycle or SEL clear Yes POST, After POST
E171F PCIE Fatal Slot # High BIOS has reported a PCIe fatal error on a component that resides in slot #. Same as above. Same as above. Same as above.
Hard Drives - Message Code: "x18xx"
Message Code Message String Message Priority Message Comments Minimum Action Required to Remove Message from LCD Exists in SEL? System Phase When Event Can Occur?
E1810 HDD ## Fault Low Hard drive ## has had a fault as determined by the SAS subsystem. AC Cycle or SEL clear Yes POST, After POST
E1811 HDD ##RbldAbrt Low Drive ## has had its rebuild aborted. AC Cycle or SEL clear Yes POST, After POST
E1812 HDD ## Removed Low Drive ## has been removed from the system. System reset or device is reseated/replaced/repaired. Yes POST, After POST
MiscellaneousMessage Code: "x19xx"
Message Code Message String Message Priority Message Comments Minimum Action Required to Remove Message from LCD Exists in SEL? System Phase When Event Can Occur?
I1910 Intrusion Low The chassis lid has been removed. Chassis lid is returned to the system. Yes Any
I1911 >3ERRsChkLog N/A User must check the system event log (SEL) for the rest of the errors on the system .Thee LCD is limited to three error, warning, and/or informational messages at a time based on priority level. Less than 3 events to display on the LCD. No Any
I1912 SEL Full Med System Event Log is full of events and because of this is unable to log anymore. You must clear the log in order for the Server Management controller to log any more events. AC Cycle or SEL clear Yes Any
E1913 CPU & Firmware Mismatch Med Current version of BMC firmware is incompatible with the Woodcrest processor. AC Cycle or SEL clear Yes POST
BIOS Progress Codes - Message Code: N/A
Message Code Message String Message Priority Message Comments Minimum Action Required to Remove Message from LCD Exists in SEL? System Phase When Event Can Occur?
N/A POWER N/A 0x01 -- System power-on. N/A No Any
N/A MCODE N/A 0x02 -- CPU Microcode load. N/A No Any
N/A CINIT N/A 0x03 -- Chipset Initialization. N/A No Any
N/A MEMC N/A 0x04 -- Memory Configuration. N/A No Any
N/A SBIOS N/A 0x05 -- BIOS shadow into memory. N/A No Any
N/A PINIT N/A 0x06 -- Multiprocessor Initialization. N/A No Any
N/A START N/A 0x07 -- POST processing start. N/A No Any
N/A SMM N/A 0x08 -- System management interrupt (SMI) initialization. N/A No Any
N/A PCIEN N/A 0x09 -- PCI Bus Enumeration & Video initialization. N/A No Any
N/A VIDEO N/A 0x40 -- Display sign-on. N/A No Any
N/A PCIC N/A 0x41 -- PCI Configuration. N/A No Any
N/A OS N/A 0x7F -- Give control to OS. N/A No Any
N/A E2010 N/A 0x80 -- No memory installed in the system. N/A No Any
N/A E2011 N/A 0x81 -- Memory detected but is not configurable .Error detected during memory configuration. Could be result of bad memory, mismatched memory or bad socket. N/A No Any
N/A E2012 N/A 0x82 -- Memory configured but not usable. Memory sub-system failure. Could be the result of bad memory. N/A No Any
N/A E2013 N/A 0x83 -- BIOS failed to copy its flash image into memory. Could be the result of bad memory. N/A No Any
N/A E2014 N/A 0x84 -- CMOS failure. CMOS'S RAM not working. N/A No Any
N/A E1215 N/A 0x05 -- DMA controller failure. N/A No Any
N/A E1116 N/A 0x80 -- Interrupt controller failure. N/A No Any
N/A E1217 N/A 0x07 -- Timer refresh failure. N/A No Any
N/A E1218 N/A 0x28 -- Programmable interval timer error. N/A No Any
N/A E0119 N/A 0x29 -- Parity error. N/A No Any
N/A E122A N/A 0x2a -- SIO failure. N/A No Any
N/A E122B N/A 0x00b0 -- Keyboard controller failure. N/A No Any
N/A E141C N/A 0x3c -- System management interrupt (SMI) initialization failure. N/A No Any
N/A E.11 N/A 0xC4 -- BIOS shutdown test failure. N/A No Any
N/A E.11 N/A 0xC4 -- BIOS POST memory test failure. Could be the result of bad memory. N/A No Any
N/A E141F N/A 0xC4 -- Dell remote access controller (DRAC) configuration failure. Check screen for the actual error message. N/A No Any
N/A E0000 N/A 0xC4 -- CPU configuration failure. Check screen for the actual error message. N/A No Any
N/A E1221 N/A 0xC4 -- Incorrect memory configuration. Memory population order not correct. Refer to the user guide. N/A No Any
N/A E1222 N/A 22x -- General failure after video. Check screen for the actual error message. N/A No Any
BIOS Fatal Error Codes - Message Code: "x20xx"
Message Code Message String Message Priority Message Comments Minimum Action Required to Remove Message from LCD Exists in SEL? System Phase When Event Can Occur?
E2010 No Memory High 0x80 -- No memory installed in the system. System reset Yes POST
E2011 MemConfigErr High 0x81 -- Memory detected but is not configurable. Error detected during memory configuration. Could be result of bad memory, mismatched memory or bad socket. System reset Yes POST
E2012 Unusable Memory High 0x82 -- Memory configured but not usable. Memory sub-system failure. Could be the result of bad memory. System reset Yes POST
E2013 Shadow BIOS Fail High 0x83 -- BIOS failed to copy its flash image into memory. Could be the result of bad memory. System reset Yes POST
E2014 CMOS Fail High 0x84 -- CMOS failure. CMOS'S RAM not working. System reset Yes POST
E2015 DMA Controller High 0x85 -- DMA controller failure. System reset Yes POST
E2016 IntController High 0x86 -- Interrupt controller failure. System reset Yes POST
E2017 Timer Fail High 0x87 -- Timer refresh failure. System reset Yes POST
E2018 ProgTimer High 0x88 -- Programmable interval timer error. System reset Yes POST
E2019 Parity Error High 0x89 -- Parity error. System reset Yes POST
E201A SIO Err High 0x8A -- SIO failure. System reset Yes POST
E201B KybdController High 0x8B -- Keyboard controller failure. System reset Yes POST
E201C SMI Init High 0x8C -- System management interrupt (SMI) initialization failure. System reset Yes POST
E201D Shutdown Test High 0xC0 -- BIOS shutdown test failure. System reset Yes POST
E201E POSTMemTest High 0xC1 -- BIOS POST memory test failure. Could be the result of bad memory. System reset Yes POST
E201F DRACConfig High 0xC2 -- Dell remote access controller (DRAC) configuration failure. Check screen for the actual error message. System reset Yes POST
E2020 CPUConfig High 0xC3 -- CPU configuration failure. Check screen for the actual error message. System reset Yes POST
E2021 Memory Population High 0xC4 -- Incorrect memory configuration. Memory population order not correct. Refer to the user guide. System reset Yes POST
E2022 POST Fail High 0xFE -- General failure after video. Check screen for the actual error message. System reset Yes POST
Special Exceptions - Message Code: "x10xx"
Message Code Message String Message Priority Message Comments Minimum Action Required to Remove Message from LCD Exists in SEL? System Phase When Event Can Occur?
E1000 Failsafe, Call Support Special Check System Event Log for critical failure details. AC Cycle or SEL clear Yes Any

DELL服务器LCD信息代码 DELL服务器LCD信息代码的意思: E1114 Temp Ambient 系统周围环境温度超出允许范围。 E1116 Temp Memory 内存已超过允许温度,系统已将其禁用以防止损组件。 E1210 CMOS Batt 缺少 CMOS 电池,或电压超出允许范围。 E1211 ROMB Batt RAID 电池丢失、损或因温度问题而无法再充电。 E12nn XX PwrGd 指定的稳压器出现故障。 E1229 CPU # VCORE 处理器 # VCORE 稳压器出现故障。 E122B 0.9V Over Voltage 0.9 V 稳压器电压已超过电压允许范围 E122C CPU Power Fault 启动处理器稳压器之后,检测到稳压器故障 E1310 RPM Fan ## 指定的冷却风扇的 RPM 超出允许的运行范围。 E1410 CPU # IERR 指定的微处理器正在告系统错误。 E1414 CPU # Thermtrip 指定的微处理器超出了允许的温度范围并已停止运行。 E1418 CPU # Presence 指定的处理器丢失或损,系统的配置不受支持。 E141C CPU Mismatch 处理器的配置不受 Dell 支持。 E141F CPU Protocol 系统 BIOS 已告处理器协议错误。 E1420 CPU Bus PERR 系统 BIOS 已告处理器总线奇偶校验错误。 E1421 CPU Init 系统 BIOS 已告处理器初始化错误。 E1422 CPU Machine Chk 系统 BIOS 已告机器检查错误。 E1618 PS # Predictive 电源设备电压超出允许范围;指定的电源设备安装错误或出现故障。 E161C PS # Input Lost 指定的电源设备的电源不可用,或超出了允许范围。 E1620 PS # Input Range 指定的电源设备的电源不可用,或超出了允许范围。 E1710 I/O Channel Chk 系统 BIOS 已告 I/O 通道检查错误。 E1711 PCI PERR B## D## F## PCI PERR Slot # 系统 BIOS 已告组件的 PCI 奇偶校验错误,该组件所在的 PCI 配置空间位于总线 ##,设备 ##,功能 ##。 系统 BIOS 已告组件的 PCI 奇偶校验错误,该组件位于 PCI 插槽 #。 E1712 PCI SERR B## D## F## PCI SERR Slot # 系统 BIOS 已告组件的 PCI 系统错误,该组件所在的 PCI 配置空间位于总线 ##,设备 ##,功能 ##。 系统 BIOS 已告组件的 PCI 系统错误,该组件位于插槽 #。 E1714 Unknown Err 系统 BIOS 已确定系统中存在错误,但无法确定错误来源。 E171F PCIE Fatal Err B## D## F## PCIE Fatal Err Slot # 系统 BIOS 已告组件的 PCIe 致命错误,该组件所在的 PCI 配置空间位于总线 ##,设备 ##,功能 ##。 系统 BIOS 已告组件的 PCIe 致命错误,该组件位于插槽 #。 卸下并重置 PCI 扩充卡。如果问题仍然存在,请参阅排除扩充卡故障。 E1913 CPU & Firmware Mismatch BMC 固件不支持 CPU。 E2010 No Memory 系统中没有安装内存。 E2011 Mem Config Err 检测到内存,但是内存不可配置。配置内存期间检测到错误。 E2012 Unusable Memory 已配置内存,但内存不可用。内存子系统出现故障。 E2013 Shadow BIOS Fail 系统 BIOS 无法将其快擦写映像复制到内存中。 E2014 CMOS Fail CMOS 出现故障。CMOS RAM 未正常工作。 E2015 DMA Controller DMA 控制器出现故障。 E2016 Int Controller 中断控制器出现故障。 E2017 Timer Fail 计时器刷新故障。 E2018 Prog Timer 可编程间隔计时器错误。 E2019 Parity Error 奇偶校验错误。 E201A SIO Err SIO 出现故障。 E201B Kybd Controller 键盘控制器出现故障。 E201C SMI Init 系统管理中断 (SMI) 初始化失败。 E201D Shutdown Test BIOS 关闭系统检测失败。 E201E POST Mem Test BIOS POST 内存检测失败。 E201F DRAC Config Dell 远程访问控制器 (DRAC) 配置失败。 E2020 CPU Config CPU 配置失败。 E2021 Memory Population 内存配置不正确。内存安装顺序不正确。 E2022 POST Fail 视频后出现一般故障。 E2110 MBE DIMM ## & ## “## & ##”指示的 DIMM 组中的一个 DIMM 发生内存多位错误 (MBE)。 E2111 SBE Log Disable DIMM ## 系统 BIOS 已禁用内存单位错误 (SBE) 记录,在重新引导系统之前,不会再记录更多的 SBE。“##”表示 BIOS 指示的 DIMM。 E2112 Mem Spare DIMM ## 系统 BIOS 确定内存中有太多错误,因此已将内存释放。“## & ##”表示 BIOS 指示的 DIMM 对。 E2113 Mem Mirror DIMM ## & ## 系统 BIOS 确定一半镜像中有太多错误,因此已将内存禁用。“## & ##”表示 BIOS 指示的 DIMM 对。 E2118 Fatal NB Mem CRC 北侧的全缓冲 DIMM (FBD) 内存子系统链接中的一个连接失败。 E2119 Fatal SB Mem CRC 南侧的 FBD 内存子系统链接中的一个连接失败。 I1910 Intrusion 主机盖被卸下。 I1911 >3 ERRs Chk Log LCD 溢出信息。 LCD 上最多只能按顺序显示三条错误信息。第四条信息显示为标准的溢出信息。 I1912 SEL Full 系统事件日志中的事件已满,无法再记录更多事件。 W1228 ROMB Batt < 24hr 预先警告 RAID 电池只剩下不足 24 小时的电量。