BW--- BW Connectivity(最佳实践适合BW3.5) (转)

BW--- BW Connectivity(最佳实践适合BW3.5)
Content

Use
With the Building Block Connectivity a configuration role for each component is provided to access all transactions relevant for the installation. The following roles are available:

Technical name
Description
File name for upload
B02_01C
B02 - Connectivity Configuration Role (SAP R/3)
B02_01C.SAP
B02_03C
B02 - Connectivity Configuration Role (SAP BW)
B02_03C.SAP
C71_04C
B02 - Connectivity Configuration Role (SAP CRM)
C71_04C.SAP
B02_04C_SRM
B02 - Connectivity Configuration Role (SAP SRM)
B02_04C_SRM.SAP
Procedure
Please upload the necessary roles and add them to your user, using transactions PFCG (Role Maintenance).
This chapter describes all local settings that are necessary for each component like SAP R/3, SAP SCM, SAP BW, SAP CRM or SAP SRM.
Use
This activity allows you to change Customizing settings.
Prerequisites
You have logged on to the system in English in order to start with the installation of the Best Practices Scenario.
Procedure
Run the following activity:

SAP R/3 Role Menu
Define Client Administration (SAP R/3)
Transaction Code
SCC4
SAP R/3 Menu
Tools à Administration à Administration à Client Administration à Client Maintenance
Then carry out the following steps:
1. Choose Display ® Change.
2. Confirm the warning message Caution: The table is cross client.
3. Select your SAP R/3 client and choose Details.
4. In the Change View Clients: Details screen, activate the following settings:
· Automatic recording of changes
· Changes to Repository and cross-client Customizing allowed
· eCATT and CATT allowed.
5. Save.
6. Go back to the SAP Easy Access menu.
Use
The purpose of this activity is to create a logical system for your SAP R/3 System. To enable communication between systems within your system landscape, you must
1. Define the systems as logical systems.
2. Assign the logical system for the SAP R/3 System to a client.
This enables the systems to recognize the target system as an RFC destination. If the logical system has already been created, skip this activity.
Logical systems are defined cross-client.
Procedure
Carry out the following steps:
1. Access the transaction using:

SAP R/3 Role Menu
Defining a Logical System for SAP R/3 (SAP R/3)
Transaction Code
SPRO
SAP R/3
IMG Menu
Basis Components (for R/3 Enterprisse: SAP Web Application Server) ® Application Link Enabling (ALE) ® Sending and Receiving Systems ® Logical systems ® Define Logical System
2. Choose New entries.
3. In the column Log System, enter a name for the logical system that you want to create.
4. In the column Name, enter a description of the logical system.

Log. System
Name
, for example DS7CLNT723
SAP R/3 System
To designate logical systems, apply the naming convention
< XXX>CLNT< NNN>
where XXX is the system name
and NNN is the client.
5. Save your entries.
A transport request for Workbench appears.
6. Select an existing request or create a new request, if necessary.
A transport request for Customizing appears.
7. Select an existing request or create a new request, if necessary.
Use
The purpose of this activity is to make an assignment for the logical system. Skip this activity if a logical system is already assigned to your client.
Procedure
Carry out the following steps:
1. Access the transaction using:

SAP R/3 Role Menu
Assign Logical System to Client
Transaction Code
SCC4
SAP R/3 Menu
Tools à Administration à Administration à Client Administration à Client Maintenance
2. Choose Display ® Change.
3. Confirm the warning message The table is cross client.
4. Select your R/3 client and choose Details.
5. Enter the name of the logical system of your SAP R/3 client.
6. Save and confirm the warning message Be careful when changing the logical system.
7. Choose Back twice.
Use
To enable communication between the SAP R/3 back-end system and the SAP SCM System, you have to create an RFC user in the SAP R/3 System.
The RFC user in the application client enables multiple RFC connections. Skip this activity if an RFC User has already been created.
Procedure
Carry out the following steps:
1. Access the transaction using:

SAP R/3 Role Menu
Creating an RFC User (SAP R/3)
Transaction Code
SU01
SAP R/3 Menu
Tools à Administration à User Maintenance à Users
2. In the User field, enter RFCUSER.
3. Choose Create.
4. On the Maintain User screen, enter the following data on the Tab entry screens:

Address
Last Name
Function
Logon data
User type
System
Password
LOGIN
Profile
Profiles
SAP_ALL
SAP_NEW
S_BI-WX_RFC
Defaults
Logon Language
EN
5. Save your entries.
Use
This activity enables you to change Customizing settings.
Prerequisites
You have logged on to the system in English to start with the installation.

Procedure
Carry out the following steps:
1. Access the transaction using:

SAP SCM Menu
Tools à Administration à Administration à Client Administration à Client Maintenance
Transaction Code
SCC4
2. In the view Display View "Clients": Overview, choose Display ® Change and confirm the message The table is cross-client.
3. Select your SCM client.
4. Choose Details.
5. In the view Change View "Clients": Details set the flags for
  • Automatic recording of changes
  • Allow CATT processes to be started
  • Changes to Repository and cross-client Customizing allowed.
6. Save and choose Back twice.
Use
The purpose of this activity is to create a logical system for your SAP SCM System. To enable communication between systems within your system landscape, you must:
1. Define the systems as logical systems.
2. Assign the logical system for the SAP SCM System to a client.
This enables the systems to recognize the target system as an RFC destination. If the logical system has already been created, skip this activity.
Logical systems are defined as cross-client.
Procedure
Carry out the following steps:
1. To define the logical system for your SAP SCM System, open the transaction using:

SAP SCM
IMG Menu
SAP R/3 Basis Customizing ® Application Link Enabling (ALE) ® Sending and Receiving Systems ® Logical Systems ® Define Logical System
Transaction Code
SPRO
2. Choose New entries.
3. In the column Log System, enter a name for the logical system that you want to create.
4. In the column Name, enter a description of the logical system.

Log. System
Name
, for example AS7CLNT001
SAP SCM System
To designate logical systems, apply the naming convention
< XXX>CLNT< NNN>
where XXX is the system name
and NNN is the client.
5. Save your entries.
A transport request for Workbench appears.
6. Select an existing request or create a new request, if necessary.
A transport request for Customizing appears.
7. Select an existing request or create a new request, if necessary.
Use
The purpose of this activity is to make an assignment for the logical system. Skip this activity if a logical system is already assigned to your client.
Procedure
Carry out the following steps:
1. Access the transaction using:

SAP SCM Menu
Tools à Administration à Administration à Client Administration à Client Maintenance
Transaction Code
SCC4
2. Choose Display ® Change.
3. Confirm the warning message The table is cross client.
4. Select your SCM client and choose Details.
5. Enter the name of the logical system of your SAP SCM client.
6. Save and confirm the warning message Be careful when changing the logical system.
7. Choose Back twice.
2.2.4

来自 “ ITPUB博客 ” ,链接:http://blog.itpub.net/10294527/viewspace-122982/,如需转载,请注明出处,否则将追究法律责任。

转载于:http://blog.itpub.net/10294527/viewspace-122982/

本 PPT 介绍了制药厂房中供配电系统的总体概念与设计要点,内容包括: 洁净厂房的特点及其对供配电系统的特殊要求; 供配电设计的一般原则与依据的国家/行业标准; 从上级电网到工厂变电所、终端配电的总体结构与模块化设计思路; 供配电范围:动力配电、照明、通讯、接地、防雷与消防等; 动力配电中电压等级、接地系统形式(如 TN-S)、负荷等级与可靠性、UPS 配置等; 照明的电源方式、光源选择、安装方式、应急与备用照明要求; 通讯系统、监控系统在生产管理与消防中的作用; 接地与等电位连接、防雷等级与防雷措施; 消防设施及其专用供电(消防泵、排烟风机、消防控制室、应急照明等); 常见高压柜、动力柜、照明箱等配电设备案例及部分设计图纸示意; 公司已完成的典型项目案例。 1. 工程背景与总体框架 所属领域:制药厂房工程的公用工程系统,其中本 PPT 聚焦于供配电系统。 放在整个公用工程中的位置:与给排水、纯化水/注射用水、气体与热力、暖通空调、自动化控制等系统并列。 2. Part 01 供配电概述 2.1 洁净厂房的特点 空间密闭,结构复杂、走向曲折; 单相设备、仪器种类多,工艺设备昂贵、精密; 装修材料与工艺材料种类多,对尘埃、静电等更敏感。 这些特点决定了:供配电系统要安全可靠、减少积尘、便于清洁和维护。 2.2 供配电总则 供配电设计应满足: 可靠、经济、适用; 保障人身与财产安全; 便于安装与维护; 采用技术先进的设备与方案。 2.3 设计依据与规范 引用了大量俄语标准(ГОСТ、СНиП、SanPiN 等)以及国家、行业和地方规范,作为设计的法规基础文件,包括: 电气设备、接线、接地、电气安全; 建筑物电气装置、照明标准; 卫生与安全相关规范等。 3. Part 02 供配电总览 从电源系统整体结构进行总览: 上级:地方电网; 工厂变电所(10kV 配电装置、变压