客户的一台SUN Fire 490 报告大量如下错误:
| Nov 17 07:36:51 XXXX-APP0 picld[139]: [ID 983929 daemon.error] Device PS1: Failure Detected -- PS1 shutdown! Nov 17 07:36:03 XXXX-APP0 last message repeated 14 times Nov 17 07:36:33 XXXX-APP0 picld[139]: [ID 983929 daemon.error] Device PS1: Failure Detected -- PS1 shutdown! Nov 17 07:42:46 XXXX-APP0 last message repeated 14 times Nov 17 07:43:16 XXXX-APP0 picld[139]: [ID 983929 daemon.error] Device PS1: Failure Detected -- PS1 shutdown! Nov 17 07:49:29 XXXX-APP0 last message repeated 14 times Nov 17 07:49:55 XXXX-APP0 picld[139]: [ID 983929 daemon.error] Device PS1: Failure Detected -- PS1 shutdown! Nov 17 07:56:16 XXXX-APP0 last message repeated 14 times |
通过prtdiag命令检查,发现是电源错误
| # prtdiag -v | more System Configuration: Sun Microsystems sun4u Sun Fire V490 System clock frequency: 150 MHz Memory size: 8192 Megabytes …………………………………………… 此处省略其他信息 --------------- Supply Status Fault Fan Fail Temp Fail ------ ------------ -------- --------- --------- PS0 [NO_FAULT ] OFF OFF OFF PS1 [DEVICE_FAIL ] ON OFF OFF ================================= |
注意上面PS1那行红色的ON
厂商售后更换电源解决问题
[@more@]来自 “ ITPUB博客 ” ,链接:http://blog.itpub.net/22049049/viewspace-1029157/,如需转载,请注明出处,否则将追究法律责任。
转载于:http://blog.itpub.net/22049049/viewspace-1029157/
客户遇到SUN Fire 490服务器频繁报告电源PS1故障的问题,表现为电源关闭并重复出现错误信息。通过prtdiag命令确认为实际的电源故障,最终由厂商售后更换电源解决了该问题。