Cable and Board Presence - Message Code: "x1Axx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
E1A10PDBPwrCableHighPDB power cable to the planar is missing or bad and system will not power on.Failing device is reseated/replaced/repaired.YesPre-Post
E1A11PCIRsrConfigHighPCI risers are not configured correctly; some invalid configurations prevent system power on.Failing device is reseated/replaced/repaired.YesPre-Post
E1A12PCIRsrMissingHighOne or all of the PCI risers is missing. This prevents system power on.Failing device is reseated/replaced/repaired.YesPre-Post
E1A14SAS Cable ALowSAS cable A is missing or bad.Failing device is reseated/replaced/repaired.YesAny
E1A15SAS Cable BLowSAS cable B is missing or bad.Failing device is reseated/replaced/repaired.YesAny
E1A16SAS Cable FBLowFlex bay SAS cable is missing or bad.Failing device is reseated/replaced/repaired.YesAny
E1A17PwrCable FBLowFlex bay power cable is missing or bad.Failing device is reseated/replaced/repaired.YesAny
E1A18PDBCtrl CableHighPDB control cable to the planar is missing or bad and system will not power on.Failing device is reseated/replaced/repaired.YesAny
Temperature - Message Code: "x11xx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
E1114Temp AmbientMedAmbient temperature has a reached a point outside of the allowed range.Temperature returns to allowable range.YesAny
E1116Temp MemoryHighMemory has exceeded allowable temperature and has been disabled to prevent damage to the components.AC Cycle or SEL clearYesAny
Voltages - Message Code: "x12xx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
E1210CMOSBattLowCMOS battery is missing or the voltage is outside of the allowable range.Failing device is reseated/replaced/repaired.YesAny
E1211ROMBBattLowPERC5I RAID battery charger has reported to the Server Management that the battery is either missing, can't charge the battery (possibly because of high temperatures), or the battery is bad.Failing device is reseated/replaced/repaired.YesAny
W1228ROMBBatt< 24 hrLowThis is a predictive failure warning message telling the user that the PERC5I RAID battery has less then 24 hours of charge left init. We provide this message as a warning message to the customer.Battery charges to > 24 hours of sustained charge.YesAny
E12141.5VPwrGdHigh1.5 VV voltage regulator has failed.AC Cycle or SEL clearYesAny
E12151.8VPwrGdHigh1.8 VV voltage regulator has failed.AC Cycle or SEL clearYesAny
E12163.3VPwrGdHigh3.3 V voltage regulator has failed.AC Cycle or SEL clearYesAny
E12175VPwrGdHigh5 V voltage regulator has failed.AC Cycle or SEL clearYesAny
E1218PCIRsr5VPwrGdHighPCI Riser 5 V voltage regulator has failed.AC Cycle or SEL clearYesAny
E1219BackplanePwrGdHighBackplane voltage regulator has failed.AC Cycle or SEL clearYesAny
E1221Flex BayPwrGdHighFlex Bay voltage regulator power good has failed.AC Cycle or SEL clearYesAny
E1222VCACHE #PwrGdHighVCACHE # voltage regulator has failed.AC Cycle or SEL clearYesAny
E1223VRM #PwrGdHighVRM # voltage regulator has failed.AC Cycle or SEL clearYesAny
E1225ESB 1.5VPwrGdHighESB 1.5 VV voltage regulator has failed.AC Cycle or SEL clearYesAny
E1226PCIRsr1.5VPwrGdHighPCI Riser 1.5 VV voltage regulator has failed.AC Cycle or SEL clearYesAny
E1227LinearPwrGdHighLinear voltage regulator(s) has failed. Represents status of multiple voltage regulators used in the video and LOM circuitry.AC Cycle or SEL clearYesAny
E12280.9VPwrGdHighMemory VTT voltage regulator has failed.AC Cycle or SEL clearYesAny
E1229CPU # VCOREHighProcessor # VCORE voltage regulator has failed.AC Cycle or SEL clearYesAny
E122ACPU VTTPwrGdHighProcessor VTT voltage regulator has failed.AC Cycle or SEL clearYesAny
E122B0.9 V Over VoltageHigh0.9 V regulator voltage has exceeded the allowable voltage range.AC Cycle or SEL clearYesAny
E122CCPU Power FaultHighA voltage regulator failure was detected when the processor regulator(s) was enabled.AC Cycle or SEL clearYesAny
Fans - Message Code: "x13xx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
E1310RPM Fan ##LowRPM of fan ## is outside of the intended operating range.Fan RPM reading returns to a point inside of the intended operating range.YesAny
E1311RPM Fan Mod #ALowRPM of fan A in the # module is outside of the intended operating range.Fan RPM reading returns to a point inside of the intended operating range.YesAny
E1311RPM Fan Mod #BLowSame as above except for fan B of module #.Fan RPM reading returns to a point inside of the intended operating range.YesAny
E1311RPM Fan Mod #CLowSame as above except for fan C of module #.Fan RPM reading returns to a point inside of the intended operating range.YesAny
E1311RPM Fan Mod #DLowSame as above except for fan D of module #.Fan RPM reading returns to a point inside of the intended operating range.YesAny
E1313Fan RedundancyLowThe system is no longer fan redundant. Another fan failure would put the system at risk of over-heating.Fan redundancy is regained, which requires all fans to be operating within the intended operating range.YesAny
Processors - Message Code: "x14xx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
E1410CPU # IERRHighProcessor # has had an internal error (IERR), but this does not always mean that CPU is the problem .There are a large variety of issues that cause an IERR.AC Cycle or SEL clearYesAny
E1414CPU #ThermtripHighProcessor # has encountered a Thermtrip(over-temperature) event.AC Cycle or SEL clearYesAny
E1418CPU # PresenceHighProcessor # is missing/bad and the system is in an unsupported configuration.AC Cycle or SEL clearYesPre-POST
E141CCPU MismatchHighProcessors are not compatible as defined by Dell .System is in an unsupported configuration.AC Cycle or SEL clearYesPre-POST
E141FCPU ProtocolHighBIOS has reported a processor protocol error.AC Cycle or SEL clearYesPOST, After POST
E1420CPU Bus PERRHighBIOS has reported a processor bus PERR (parity error).AC Cycle or SEL clearYesPOST, After POST
E1421CPU InitHighBIOS has reported a processor initialization error.AC Cycle or SEL clearYesPOST, After POST
E1422CPU MachineChkHighBIOS has reported a machine check error.AC Cycle or SEL clearYesPOST, After POST
System Memory - Message Code: "x21xx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
E2110MBECrdx DIMM ## & ##HighOne of the DIMMs in the set implicated by "## & ##" has had a multi-bit error (MBE).If no memory riser is present the “Crdx” string is left out of the message.“x” is the memory riser, A-Z.AC Cycle or SEL clearYesPOST, After POST
E2111SBE Log DisableCrdx DIMM ##HighBIOS has disabled memory single-bit error (SBE) logging and will not log anymore SBEE's until the system is rebooted.## represents DIMM implicated by BIOS .If no memory riser is present the “Crd x” string is left out of the message.“x” is the memory riser, A-Z.System resetYesPOST, After POST
E2112MemSpareCrdx DIMM ##HighBIOS has spared the memory because it has determined the memory had too many errors.## represents DIMM implicated by BIOS. If no memory riser is present the “Crdx” string is left out of the message.“x” is the memory riser, A-Z.System resetYesPOST, After POST
E2113Mem Mirror Crd x DIMM ## & ##HighBIOS has disabled memory mirroring because it has determined one half of the mirror has had too many errors. ## & ## represents DIMM pair implicated by BIOS. If no memory riser is present the “Crdx” string is left out of the message.“x” is the memory riser, A-Z.System resetYesPOST, After POST
I2114MemRaidLowBIOS Memory RAID BankUser action, sensor return to normalYesAny
I2115MemAdded Card xLowMemory has been added while the system is running.AC Cycle or SEL clearYesAny
I2116MemRemovedLowMemory has been removed while the system is running.AC Cycle or SEL clearYesAny
E2117MemHot PlugLowMemory hot-plug operation has failed.AC Cycle or SEL clearYesAny
E2118Fatal NBMemCRCHighNorthbound FBD CRC error on non-redundant entry. One of the connections in the FBD link on the Northbound (towards the MCH) side is "broken".This is determined by the MCH when two CRC errors have been detected twice in a row.AC Cycle or SEL clearYesPOST, After POST
E2119Fatal SBMemCRCHighFBD alert on non-redundant entry. One of the connections in the FBD link on the Southbound (towards the AMB'son the FBDIMM's) side is "broken".This is determined by the MCH when two CRC errors have been detected twice in a row.AC Cycle or SEL clearYesPOST, After POST

 

Power Supplies - Message Code: "x16xx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
E1610PS # MissingLowPower supply # was removed or is missing from the system.Failing device is reseated/replaced/repaired.YesAny
E1614PS # StatusLowPower supply # has failed.Failing device is reseated/replaced/repaired.YesAny
E1618PS # PredictiveLowPower supply # has a failure that predicts a power down event in this supply (i.e. power supply fan failure or power supply over-temp).Failing device is reseated/replaced/repaired.YesAny
E161CPS # Input LostLowPower supply # is attached to the system but has lost its AC/DC input.Failing device is reseated/replaced/repaired.YesAny
E1620PS #Input RangeLowPower supply #'s AC/DC input is outside of the allowable range.Failing device is reseated/replaced/repaired.YesAny
E1624PS RedundancyLowThe power supply subsystem is no longer redundant. If the last supply fails the system will go down.Failing device is reseated/replaced/repaired.YesAny
E1625PS AC CurrentLowThe power supply input power is above the allowed amount for the power supply.Failing device is reseated/replaced/repaired.YesAny
BIOS - Message Code: "x17xx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
E1710I/O ChannelChkHighBIOS has reported an I/O channel check.AC Cycle or SEL clearYesPOST, After POST
E1711PCI PERR B## D## F##HighBIOS has reported PCI parity error on a component that resides in PCI configuration space at bus ##, device ##, function ##.AC Cycle or SEL clearYesPOST, After POST
E1711PCI PERR Slot #HighBIOS has reported PCI parity error on a component that resides in slot #.Same as above.Same as above.Same as above.
E1712PCI SERR B## D## F##HighBIOS has reported a PCI system error on a component that resides in PCI configuration space at bus ##, device ##, function ##.AC Cycle or SEL clearYesPOST, After POST
E1712PCI SERR Slot #HighBIOS has reported a PCI system error on a component that resides in slot #.Same as above.Same as above.Same as above.
E1714Unknown ErrLowBIOS has determined there has been an error in the system but is unable to determine its origin.AC Cycle or SEL clearYesPOST, After POST
E171FPCIE Fatal Err B## D## F##HighBIOS has reported a PCIe fatal error on a component that resides in PCI configuration space at bus ##, device ##, function ##.AC Cycle or SEL clearYesPOST, After POST
E171FPCIE Fatal Slot #HighBIOS has reported a PCIe fatal error on a component that resides in slot #.Same as above.Same as above.Same as above.
Hard Drives - Message Code: "x18xx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
E1810HDD ## FaultLowHard drive ## has had a fault as determined by the SAS subsystem.AC Cycle or SEL clearYesPOST, After POST
E1811HDD ##RbldAbrtLowDrive ## has had its rebuild aborted.AC Cycle or SEL clearYesPOST, After POST
E1812HDD ## RemovedLowDrive ## has been removed from the system.System reset or device is reseated/replaced/repaired.YesPOST, After POST
Miscellaneous - Message Code: "x19xx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
I1910IntrusionLowThe chassis lid has been removed.Chassis lid is returned to the system.YesAny
I1911>3ERRsChkLogN/AUser must check the system event log (SEL) for the rest of the errors on the system .Thee LCD is limited to three error, warning, and/or informational messages at a time based on priority level.Less than 3 events to display on the LCD.NoAny
I1912SEL FullMedSystem Event Log is full of events and because of this is unable to log anymore. You must clear the log in order for the Server Management controller to log any more events.AC Cycle or SEL clearYesAny
E1913CPU & Firmware MismatchMedCurrent version of BMC firmware is incompatible with the Woodcrest processor.AC Cycle or SEL clearYesPOST
BIOS Progress Codes - Message Code: N/A
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
N/APOWERN/A0x01 -- System power-on.N/ANoAny
N/AMCODEN/A0x02 -- CPU Microcode load.N/ANoAny
N/ACINITN/A0x03 -- Chipset Initialization.N/ANoAny
N/AMEMCN/A0x04 -- Memory Configuration.N/ANoAny
N/ASBIOSN/A0x05 -- BIOS shadow into memory.N/ANoAny
N/APINITN/A0x06 -- Multiprocessor Initialization.N/ANoAny
N/ASTARTN/A0x07 -- POST processing start.N/ANoAny
N/ASMMN/A0x08 -- System management interrupt (SMI) initialization.N/ANoAny
N/APCIENN/A0x09 -- PCI Bus Enumeration & Video initialization.N/ANoAny
N/AVIDEON/A0x40 -- Display sign-on.N/ANoAny
N/APCICN/A0x41 -- PCI Configuration.N/ANoAny
N/AOSN/A0x7F -- Give control to OS.N/ANoAny
N/AE2010N/A0x80 -- No memory installed in the system.N/ANoAny
N/AE2011N/A0x81 -- Memory detected but is not configurable .Error detected during memory configuration. Could be result of bad memory, mismatched memory or bad socket.N/ANoAny
N/AE2012N/A0x82 -- Memory configured but not usable. Memory sub-system failure. Could be the result of bad memory.N/ANoAny
N/AE2013N/A0x83 -- BIOS failed to copy its flash image into memory. Could be the result of bad memory.N/ANoAny
N/AE2014N/A0x84 -- CMOS failure. CMOS'S RAM not working.N/ANoAny
N/AE1215N/A0x05 -- DMA controller failure.N/ANoAny
N/AE1116N/A0x80 -- Interrupt controller failure.N/ANoAny
N/AE1217N/A0x07 -- Timer refresh failure.N/ANoAny
N/AE1218N/A0x28 -- Programmable interval timer error.N/ANoAny
N/AE0119N/A0x29 -- Parity error.N/ANoAny
N/AE122AN/A0x2a -- SIO failure.N/ANoAny
N/AE122BN/A0x00b0 -- Keyboard controller failure.N/ANoAny
N/AE141CN/A0x3c -- System management interrupt (SMI) initialization failure.N/ANoAny
N/AE.11N/A0xC4 -- BIOS shutdown test failure.N/ANoAny
N/AE.11N/A0xC4 -- BIOS POST memory test failure. Could be the result of bad memory.N/ANoAny
N/AE141FN/A0xC4 -- Dell remote access controller (DRAC) configuration failure. Check screen for the actual error message.N/ANoAny
N/AE0000N/A0xC4 -- CPU configuration failure. Check screen for the actual error message.N/ANoAny
N/AE1221N/A0xC4 -- Incorrect memory configuration. Memory population order not correct. Refer to the user guide.N/ANoAny
N/AE1222N/A22x -- General failure after video. Check screen for the actual error message.N/ANoAny
BIOS Fatal Error Codes - Message Code: "x20xx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
E2010No MemoryHigh0x80 -- No memory installed in the system.System resetYesPOST
E2011MemConfigErrHigh0x81 -- Memory detected but is not configurable. Error detected during memory configuration. Could be result of bad memory, mismatched memory or bad socket.System resetYesPOST
E2012Unusable MemoryHigh0x82 -- Memory configured but not usable. Memory sub-system failure. Could be the result of bad memory.System resetYesPOST
E2013Shadow BIOS FailHigh0x83 -- BIOS failed to copy its flash image into memory. Could be the result of bad memory.System resetYesPOST
E2014CMOS FailHigh0x84 -- CMOS failure. CMOS'S RAM not working.System resetYesPOST
E2015DMA ControllerHigh0x85 -- DMA controller failure.System resetYesPOST
E2016IntControllerHigh0x86 -- Interrupt controller failure.System resetYesPOST
E2017Timer FailHigh0x87 -- Timer refresh failure.System resetYesPOST
E2018ProgTimerHigh0x88 -- Programmable interval timer error.System resetYesPOST
E2019Parity ErrorHigh0x89 -- Parity error.System resetYesPOST
E201ASIO ErrHigh0x8A -- SIO failure.System resetYesPOST
E201BKybdControllerHigh0x8B -- Keyboard controller failure.System resetYesPOST
E201CSMI InitHigh0x8C -- System management interrupt (SMI) initialization failure.System resetYesPOST
E201DShutdown TestHigh0xC0 -- BIOS shutdown test failure.System resetYesPOST
E201EPOSTMemTestHigh0xC1 -- BIOS POST memory test failure. Could be the result of bad memory.System resetYesPOST
E201FDRACConfigHigh0xC2 -- Dell remote access controller (DRAC) configuration failure. Check screen for the actual error message.System resetYesPOST
E2020CPUConfigHigh0xC3 -- CPU configuration failure. Check screen for the actual error message.System resetYesPOST
E2021Memory PopulationHigh0xC4 -- Incorrect memory configuration. Memory population order not correct. Refer to the user guide.System resetYesPOST
E2022POST FailHigh0xFE -- General failure after video. Check screen for the actual error message.System resetYesPOST
Special Exceptions - Message Code: "x10xx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
E1000Failsafe, Call SupportSpecialCheck System Event Log for critical failure details.AC Cycle or SEL clearYesAny
DELL服务器LCD信息代码 DELL服务器LCD信息代码的意思: E1114 Temp Ambient 系统周围环境温度超出允许范围。 E1116 Temp Memory 内存已超过允许温度,系统已将其禁用以防止损坏组件。 E1210 CMOS Batt 缺少 CMOS 电池,或电压超出允许范围。 E1211 ROMB Batt RAID 电池丢失、损坏或因温度问题而无法再充电。 E12nn XX PwrGd 指定的稳压器出现故障。 E1229 CPU # VCORE 处理器 # VCORE 稳压器出现故障。 E122B 0.9V Over Voltage 0.9 V 稳压器电压已超过电压允许范围 E122C CPU Power Fault 启动处理器稳压器之后,检测到稳压器故障 E1310 RPM Fan ## 指定的冷却风扇的 RPM 超出允许的运行范围。 E1410 CPU # IERR 指定的微处理器正在报告系统错误。 E1414 CPU # Thermtrip 指定的微处理器超出了允许的温度范围并已停止运行。 E1418 CPU # Presence 指定的处理器丢失或损坏,系统的配置不受支持。 E141C CPU Mismatch 处理器的配置不受 Dell 支持。 E141F CPU Protocol 系统 BIOS 已报告处理器协议错误。 E1420 CPU Bus PERR 系统 BIOS 已报告处理器总线奇偶校验错误。 E1421 CPU Init 系统 BIOS 已报告处理器初始化错误。 E1422 CPU Machine Chk 系统 BIOS 已报告机器检查错误。 E1618 PS # Predictive 电源设备电压超出允许范围;指定的电源设备安装错误或出现故障。 E161C PS # Input Lost 指定的电源设备的电源不可用,或超出了允许范围。 E1620 PS # Input Range 指定的电源设备的电源不可用,或超出了允许范围。 E1710 I/O Channel Chk 系统 BIOS 已报告 I/O 通道检查错误。 E1711 PCI PERR B## D## F## PCI PERR Slot # 系统 BIOS 已报告组件的 PCI 奇偶校验错误,该组件所在的 PCI 配置空间位于总线 ##,设备 ##,功能 ##。 系统 BIOS 已报告组件的 PCI 奇偶校验错误,该组件位于 PCI 插槽 #。 E1712 PCI SERR B## D## F## PCI SERR Slot # 系统 BIOS 已报告组件的 PCI 系统错误,该组件所在的 PCI 配置空间位于总线 ##,设备 ##,功能 ##。 系统 BIOS 已报告组件的 PCI 系统错误,该组件位于插槽 #。 E1714 Unknown Err 系统 BIOS 已确定系统中存在错误,但无法确定错误来源。 E171F PCIE Fatal Err B## D## F## PCIE Fatal Err Slot # 系统 BIOS 已报告组件的 PCIe 致命错误,该组件所在的 PCI 配置空间位于总线 ##,设备 ##,功能 ##。 系统 BIOS 已报告组件的 PCIe 致命错误,该组件位于插槽 #。 卸下并重置 PCI 扩充卡。如果问题仍然存在,请参阅排除扩充卡故障。 E1913 CPU & Firmware Mismatch BMC 固件不支持 CPU。 E2010 No Memory 系统中没有安装内存。 E2011 Mem Config Err 检测到内存,但是内存不可配置。配置内存期间检测到错误。 E2012 Unusable Memory 已配置内存,但内存不可用。内存子系统出现故障。 E2013 Shadow BIOS Fail 系统 BIOS 无法将其快擦写映像复制到内存中。 E2014 CMOS Fail CMOS 出现故障。CMOS RAM 未正常工作。 E2015 DMA Controller DMA 控制器出现故障。 E2016 Int Controller 中断控制器出现故障。 E2017 Timer Fail 计时器刷新故障。 E2018 Prog Timer 可编程间隔计时器错误。 E2019 Parity Error 奇偶校验错误。 E201A SIO Err SIO 出现故障。 E201B Kybd Controller 键盘控制器出现故障。 E201C SMI Init 系统管理中断 (SMI) 初始化失败。 E201D Shutdown Test BIOS 关闭系统检测失败。 E201E POST Mem Test BIOS POST 内存检测失败。 E201F DRAC Config Dell 远程访问控制器 (DRAC) 配置失败。 E2020 CPU Config CPU 配置失败。 E2021 Memory Population 内存配置不正确。内存安装顺序不正确。 E2022 POST Fail 视频后出现一般故障。 E2110 MBE DIMM ## & ## “## & ##”指示的 DIMM 组中的一个 DIMM 发生内存多位错误 (MBE)。 E2111 SBE Log Disable DIMM ## 系统 BIOS 已禁用内存单位错误 (SBE) 记录,在重新引导系统之前,不会再记录更多的 SBE。“##”表示 BIOS 指示的 DIMM。 E2112 Mem Spare DIMM ## 系统 BIOS 确定内存中有太多错误,因此已将内存释放。“## & ##”表示 BIOS 指示的 DIMM 对。 E2113 Mem Mirror DIMM ## & ## 系统 BIOS 确定一半镜像中有太多错误,因此已将内存禁用。“## & ##”表示 BIOS 指示的 DIMM 对。 E2118 Fatal NB Mem CRC 北侧的全缓冲 DIMM (FBD) 内存子系统链接中的一个连接失败。 E2119 Fatal SB Mem CRC 南侧的 FBD 内存子系统链接中的一个连接失败。 I1910 Intrusion 主机盖被卸下。 I1911 >3 ERRs Chk Log LCD 溢出信息。 LCD 上最多只能按顺序显示三条错误信息。第四条信息显示为标准的溢出信息。 I1912 SEL Full 系统事件日志中的事件已满,无法再记录更多事件。 W1228 ROMB Batt < 24hr 预先警告 RAID 电池只剩下不足 24 小时的电量。