一般确定data from the failed drive is reconstructed on the hot spare,硬盘又亮故障灯,就可以拔下,然后插入新盘以替换,但在拔下和替换的过程中,应该软件连入监控;
可以使用容量相同或更大容量的硬盘替换故障硬盘(146G硬盘更换73G硬盘);
下面错误一般说明有硬盘故障;
errpt
IDENTIFIER TIMESTAMP T C RESOURCE_NAME DESCRIPTION
09890235 0924101011 P H hdisk9 ARRAY DRIVE FAILURE
09890235 0924101011 P H hdisk8 ARRAY DRIVE FAILURE
09890235 0924101011 P H hdisk7 ARRAY DRIVE FAILURE
09890235 0924101011 P H hdisk6 ARRAY DRIVE FAILURE
---------------------------------------------------------------------------
---------------------------------------------------------------------------
---------------------------------------------------------------------------
errpt -a
LABEL: FCP_ARRAY_ERR14
IDENTIFIER: 09890235
Date/Time: Sat Sep 24 10:10:29 BEIS
Sequence Number: 904
Machine Id: 0020245B4C00
Node Id: P670A
Class: H
Type: PERM
Resource Name: hdisk9
Resource Class: disk
Resource Type: array
Location: U1.9-P1-I7/Q1-W200600A0B8212780-L7000000000000
Description
ARRAY DRIVE FAILURE
Probable Causes
ARRAY DASD DEVICE
ARRAY DASD MEDIA
Failure Causes
ARRAY DASD MEDIA
Recommended Actions
PERFORM PROBLEM DETERMINATION PROCEDURES
Detail Data
SENSE DATA
0600 0308 0000 FF00 0000 0004 0000 0000 0000 0000 0000 0000 0000 0000 7000 0600
0000 0098 0000 0000 3F80 2400 0000 0000 0000 0000 0000 800C 0000 0000 0000 0000
0008 0500 0000 0000 0000 0000 0000 0000 0000 3154 3630 3837 3234 3730 2020 2020
2020 0612 1600 0007 0100 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0005 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 36EC 12E3 3039 3233 3131 2F31 3735 3631 3700 0000 0000 0000 0000 0000
0000 0000 3500 F000 F205 2A02 0000 0000 0000 0000 0000 0000 E800 E200 0000 0000
0000 0000
本文介绍了如何通过errpt命令检查硬盘故障,并提供了详细的故障信息示例。此外,还介绍了在发现故障时如何正确地使用热备盘进行数据重建及硬盘替换流程。
6101

被折叠的 条评论
为什么被折叠?